Sfax, Tunisia

HQ buidling of the Company for Studies and Development of North Coast of the City of Sfax (SEACNVS)

The SEACNVS built its HQ building in Taparura, Sfax in 2017. This Office building comprises 3 floors and has in total a built-up area of 1376 m². It forms part of a five-floor block, including two residential floors at the top. The main measures to save energy are thermal insulation of the exterior walls and basement of the ground floor, treatment of thermal bridges, the use of efficient bay windows, the installation of an efficient lighting system and the installation of an efficient heating and cooling system. The implementation of these measures has resulted in an annual energy saving of around 45.2 MWh in electricity.

Project info

Construction phase
New construction
Building type
Non-residential building
Detailed building type
Office
Net floor area
1376 m2
Land plot size
1273 m2
Stories
3 stories
Construction type
Mixed construction
Original construction year of the building
2017
Project contact
Company for Studies and Development of the North Coast of the City of Sfax (SEACNVS)
Contact email address
projet.taparura@seacnvs.com.tn

Project team

Developer(s)/owner(s)
Company for Studies and Development of the North Coast of the City of Sfax (SEACNVS)
Architect(s)
Mr. Lotfi Rejeb
Energy efficiency consultant(s)
Arch.: Mr. Ahmed Frikha & Eng.: Mr. Adel Gabsi

Building Rating and Certifications systems

Rating and certifications systems
Other
Other certification
The building has acheived the 1st rating per the Tunisian Thermal Regulation (62 kWh/m².a)

Building Envelope

External walls

Description of construction
Basement: Double brick walls with rock wool and plaster (N/W façades) or compressed earth and exterior polystyrene (E/S). Upper floors: Double brick with rock wool and plaster (N/E/W), with exterior polystyrene on the south façade.
U-Value
0.91 W/(m²*K)

Roof

Roof type
Flat roof
Description of construction
Not relevant - The roof of the second floor is an adjacent floor between the second and third floors and is therefore not exposed.

Openings and windows

Glazing type
Double glazed
U-Value glass
1.6 W/(m²*K)
Frame material / description
The frame is constructed from aluminum.
Overall u-value window
1.9 W/(m²*K)
Description of construction
The bay windows and windows are constructed with an aluminum frame and 6/6/6mm bronze double glazing.

Basement floor

Description of construction
The basement floor is constructed with a 25 cm reinforced concrete slab insulated with a 10 cm lightweight concrete screed.
U-Value
1 W/(m²*K)

Technical Building Systems

Ventilation system

Type of ventilation
Free ventilation (windows)

Space cooling system

Primary space cooling system
Reversible air-water heat pump
Efficiency
3.2
Description
The cooling system uses energy-efficient reversible air-water heat pumps with fan coils. Variable speed pumps circulate water, and two-way modulating valves adjust flow. The system is managed by a GTB control system.

Space heating system

Primary Space heating system
Heat Pump (air-water)
Description
The reversible cooling system also serves the dual purpose of providing space heating for the building.

Water heater system

Primary water heater system
Dedicated electric heater (dedicated = just hot water generation)
Efficiency
98

Lighting system

Primary lighting system
Linear fluorescent lamps (LFL)
Efficiency
90
Description
The lighting system includes T5 LFLs with electronic ballasts and CFLs in offices, T5 LFLs in parking areas, and LED spotlights in toilets, terraces, and the entrance porch. Presence sensors control lighting in toilets, corridors, and parking areas.
Secondary lighting system
LED (Light emitting diode lamps)
Description
The lighting system includes T5 LFLs with electronic ballasts and CFLs in offices, T5 LFLs in parking areas, and LED spotlights in toilets, terraces, and the entrance porch. Presence sensors control lighting in toilets, corridors, and parking areas.

Photovoltaics

Capacity
7 kWp

Final Energy Demand

Energy carrier (1)
Electricity
Total specific final energy demand
86 kWh/(m²*a)