Sfax, Tunisia

Energy renovation of the house of Taieb Al-Mhiri Football Stadium maintenance manager.

The municipality of Sfax renovated the house of Taieb Al-Mhiri Football Stadium maintenance manager in Sfax, in 2015. This Single Family House - detached (villa) comprises 2 floors and has in total a built-up area of 211 m². The villa comprises two distinct parts: the first, constructed in 1990, and the second a more recent addition. The two parts of the building were constructed using different materials. The main measures implemented to save energy are thermal insulation of the roof and exterior walls, installation of new double glazed PVC windows, window shades, new energy efficient lamps, new energy efficient split ACs, new energy efficient refrigerator, a solar water heater, a grid-connected PV system, and an energy management system. These measures resulted in annual energy savings of around 70%.

Project info

Construction phase
Refurbishment
Building type
Single Family House (SFH)
Detailed building type
Single Family House (SFH) - detached
Net floor area
211 m2
Stories
2 stories
Construction type
Mixed construction
Original construction year of the building
1990
Project contact
Municipality of Sfax.
Contact email address
riadhhajtaieb2040@gmail.com

Project team

Developer(s)/owner(s)
Municipality of Sfax.
Energy efficiency consultant(s)
Mr. Mohamed Bouallègue

Building Rating and Certifications systems

Rating and certifications systems
Other
Other certification
RELS methodology.

Building Envelope

External walls

Description of construction
The existing external walls have been thermally insulated using a Rockwool complex for façade insulation, comprising a 5 cm Rockwool panel layer and a thin single-layer exterior coating.
U-Value
0.467 W/(m²*K)

Roof

Roof type
Flat roof
Description of construction
The existing roof is insulated with an exterior system. It includes: 4cm Rockwool panel glued with bituminous glue, 0.4cm waterproofing membrane, 1cm screened sand, 3cm cement mortar with splitting joints, and a peripheral joint with the acroterae.
U-Value
0.654 W/(m²*K)

Openings and windows

Glazing type
Double glazed
U-Value glass
2.698 W/(m²*K)
Overall u-value window
2.558 W/(m²*K)
Description of construction
The windows are constructed with frames made from PVC and fitted with clear double glazing, with a thickness of 5/10/5 mm.

Basement floor

U-Value
2.192 W/(m²*K)

Technical Building Systems

Ventilation system

Type of ventilation
Free ventilation (windows)

Space cooling system

Primary space cooling system
Mounted single-split or window air conditioner│Usually a visible smaller system mounted outside the wall or above the window just supplying one room
Efficiency
3.40
Manufacturer(s) / products
Coala

Space heating system

Primary Space heating system
Air-conditioning system (reversible for heating; air-air heat pump)
Manufacturer(s) / products
Coala

Water heater system

Primary water heater system
Solar Thermal collector on the roof
Description
The solar water heater installed comprises a solar thermal collector with a surface area of 4 m² and a storage tank with a capacity of 300 litres.
Manufacturer(s) / products
Aquasolar

Lighting system

Primary lighting system
LED (Light emitting diode lamps)
Efficiency
80
Description
The LED lamps used are 5 W power and have a luminous efficiency of 80 lum/W.

Shading devices

Type of shading system installed
Static (fix) shading systems as part of the building architecture (e.g. Maschrabiyya, porch roofs, pergolas)
Description
Shading elements has been installed to prevent undesired direct solar irradiation from entering the building. The sunshades installed are manufactured from aluminium and are shaped like an aeroplane wing. The shading elements are 21 cm wide and have been installed in a vertical configuration, with a distance of 25 cm between each one for windows facing east, west, northeast, northwest and southeast.

Photovoltaics

Capacity
2 kWp

Final Energy Demand

Energy carrier (1)
Electricity
Annual heating demand
4.58 kWh/(m²*a)
Annual cooling demand
11.17 kWh/(m²*a)
Annual lighting demand
3.52 kWh/(m²*a)
Annual hot water demand
5.66 kWh/(m²*a)
Total specific final energy demand
30,41 kWh/(m²*a)