HAD SOUALEM , Morocco
Villa Verde/Villas CHADA
The Villas Verde project is one of the first projects in Morocco to respect the new national thermal regulations (RTCM). Spread over an area of 50,000m², the project "Villa CHADA", is located in the third phase of the urban and industrial pole Al Omrane Sahel and conveniently located by the highway and the National Road No. 1 (Casa-El Jadida). It consists of 108 finished villas, two amenities of general interest and two spaces for games, sports and green spaces.
Project info
- Construction phase
- New construction
- Building type
- Single Family House (SFH)
- Detailed building type
- Single Family House (SFH) - detached
- Net floor area
- 224 m2
- Land plot size
- 50000 m2
- Stories
- 2 stories
- Construction type
- Mixed construction
- Original construction year of the building
- 2017
- Project contact
- Kamal MALTOUFI
- Contact email address
- k.maltoufi@alomrane.gov.ma
Project team
- Developer(s)/owner(s)
- Contractor & Holding Al Omrane
- Architect(s)
- KABBAJ architecte
- Construction contractor(s)
- Al Omrane Lakhiayta
Building Rating and Certifications systems
- Rating and certifications systems
- Not applicable
Building Envelope
External walls
- Description of construction
- Mortar, Bricks, Mortar
- U-Value
- 0.60 W/(m²*K)
Roof
- Roof type
- Single Pitch Roof
- Description of construction
- Mechanical protection, Bitumen-cardboard Felts and flexible screeds Impregnated, Eps, Unidirectional floor
- U-Value
- 0.65 W/(m²*K)
Openings and windows
- Glazing type
- Single glazed
- Frame material / description
- Single glazed: 44.2 Stratobel, 2x Planibel, Clearlite with Stadip./ Double glazed: Planibel, Air blade, Planibel Clearlite with Stadip
- Overall u-value window
- 5.88 W/(m²*K)
- Description of construction
- There are both single and double glazed windows with 5.88 and 3.3 U value
Basement floor
- Description of construction
- N/A
Technical Building Systems
Ventilation system
- Type of ventilation
- Free ventilation (windows)
- Description
- Natural ventilation/ A very careful architectural design with large openings and bay windows allowing optimal natural ventilation and clean air quality
Space cooling system
- Primary space cooling system
- Solar cooling
Water heater system
- Primary water heater system
- Solar Thermal collector on the roof
- Description
- 200 liter solar water heater
Lighting system
- Primary lighting system
- LED (Light emitting diode lamps)
- Efficiency
- 100
- Description
- N/A
Shading devices
- Type of shading system installed
- Static (fix) shading systems as part of the building architecture (e.g. Maschrabiyya, porch roofs, pergolas)
- Description
- Terracotta brick for the interior walls which receive winter solar radiation
Photovoltaics
- Capacity
- 2 kWp
Final Energy Demand
- Total specific final energy demand
- 193 kWhep/m².an kWh/(m²*a)
Primary Energy Demand & Emissions
- CO2e emissions
- 5 kg/(m²*a)
Financial Aspects
- Project construction cost
- 140000 EUR