Casablanca, Morocco
House "O"
The building has a regular, well-compacted shape offering great thermal performance stimulated by the characteristics of the patio house. On the one hand, climate control can correspond to general logics such as horizontal and vertical air circulation, which allows aeration and ventilation, to push hot air upwards. The patio is shaded a large part of the day, but this role is determined in relation to its width and height, it behaves like a thermal regulator; in winter, it lets the sun penetrate the interior of the house, to store its heat there, and to raise the ambient temperature.
Project info
- Construction phase
- New construction
- Building type
- Single Family House (SFH)
- Detailed building type
- Single Family House (SFH) - detached
- Net floor area
- 411 m2
- Land plot size
- 629 m2
- Stories
- 2 stories
- Construction type
- Mixed construction
- Original construction year of the building
- 2018
- Project contact
- Myriam Soussan & Laurent Moulin architects
- Contact email address
- archibionik@gmail.com
Project team
- Developer(s)/owner(s)
- N/A
- Architect(s)
- Myriam Soussan et Laurent Moulin
- Construction contractor(s)
- Omar SEFRAOUI
Building Rating and Certifications systems
- Rating and certifications systems
- Not applicable
Building Envelope
External walls
- U-Value
- 0.56 W/(m²*K)
Roof
- Roof type
- Flat roof
- Description of construction
- Insulating and waterproofing compression slab
- U-Value
- 2.45 W/(m²*K)
Openings and windows
- Glazing type
- Double glazed
- Frame material / description
- Glass, Air blade, Glass
- Overall u-value window
- 2.45 W/(m²*K)
Basement floor
- Description of construction
- Compression slab, Insulating, Sealing
- U-Value
- 0.51 W/(m²*K)
Technical Building Systems
Space heating system
- Primary Space heating system
- Stove (usually biomass or coal)
- Description
- GREEN HOUSE EFFECT & FIRE PLACE
Water heater system
- Primary water heater system
- Solar Thermal collector on the roof
Lighting system
- Primary lighting system
- LED (Light emitting diode lamps)
- Efficiency
- 100
Shading devices
- Type of shading system installed
- Manual systems (e.g. roller shutters, folding shutters, external blinds)
- Description
- WOOD SHUTTER, SUN BLOKER & RECESSED FAÇADE
Photovoltaics
- Capacity
- 2 kWp
Final Energy Demand
- Total specific final energy demand
- N/A kWh/(m²*a)